Bluon Energy LLC develops and manufactures energy-focused HVAC refrigerants. It provides TdX 20 for commercial and residential air conditioning and heat pumps. The company was incorporated in 2011 and is based in McClellan, California.
Call Girls Miyapur 7001305949 all area service COD available Any Time
Bluon TdX 20 Advantages - Bluon HVAC Solutions
1. TdX Data Sheet
Bringing energy efficiency and a lower carbon footprint to HVAC-R.
Bluon TdX™ 20 is a new generation of refrigerant delivering substantial
energy savings, equal to or better R-22 capacity and easy installation.
Bluon TdX 20 is a patent-pending, energy-focused refrigerant replacement for
R-22 HVAC equipment. TdX 20 is the only refrigerant purpose built for energy
efficiency, equal to or superior cooling capacity and cost savings.
When it comes to options for eliminating R-22 to achieve environmental
compliance there are essentially two choices: 1) Replace the R-22 units with
new R-410A equipment; or 2) Replace the R-22 refrigerant and keep the
existing equipment until the end of its lifespan.
While R-410A equipment is the industry’s answer for achieving R-22 phase-out
compliance, the cost at $2,500 per ton is a drawback. Replacing the R-22
refrigerant only is a more cost effective option, particularly when your equipment
has remaining lifespan. But not all R-22 replacement refrigerants are alike. Most
consume more energy, provide less capacity or require an oil change. And then
there's Bluon TdX 20, created to be the R-22 replacement answer. When you install
TdX 20, you attain environmental compliance, maintain capacity and save energy.
Bluon TdX 20 Advantages
Reduces energy consumption in HVAC equipment an average of 20% through
lower amp draw and reduced equipment run time.
Complies with R-22 phase-out as a non-ozone depleting refrigerant.
Delivers equipment capacity equal to, or greater than, R-22.
Extends equipment life through lower operating pressures, reduced
compressor temperatures and shorter cycle times.
Is the only alternative refrigerant that pays for itself, through lower energy
consumption, providing an attractive financial return with a payback of ~24
months of operations.
Improves overall system performance through faster more consistent cooling.
DATA SHEET
2. 2 TdX Data Sheet
Performance Benefits
HVAC equipment running TdX 20 uses 20% less energy on average.
Decreases unit amp draw by 5–25% and daily run time from 20–90 minutes.
Decreases energy consumption during utility peak load times.
Runs in low, medium and high temperature systems. Optimized for medium and
high temperature equipment.
Preserves or increases the cooling capacity compared to R-22.
Installation and Equipment Benefits
Extends the life of your current R-22 equipment through lower pressures, lower
compressor operating temperatures and less run time.
Works with standard metering devices. No expansion device change is required.
Works with standard compressor oils including POE, AB and MO. No oil change
required.
Runs on all R-22 HVAC equipment
Avoids a significant capital investment for new R-410A equipment.
Environmental Benefits
Non-ozone depleting.
GWP of 1,650, the lowest GWP for R-22 replacement refrigerants available.
Non-flammable and non-toxic.
Helps property owners gain points toward LEED certification.
A 100,000 sq. ft. building replacing R-22 with Bluon TdX 20 will reduce its
carbon footprint by 60 metric tons of CO2 per year as illustrated in a third party
engineering study.
TdX 20 Saves Energy, Lowers Your Building’s Carbon Footprint
TdX 20 was purposely designed with an energy conservation focus. Third party engineering
studies and hundreds of field tests validate TdX’s average energy savings of 20%. The kWh
savings is achieved through reduced amp draw at the compressor combined with a shorter
compressor cycle time. TdX 20’s composition reduces the time it takes an HVAC unit to reach
optimal cooling/heating temperature and thus decreases the amount of time and electricity
needed to cool or heat a space. With the reduction in energy consumption using TdX 20, a
substantial decrease in CO2 emissions from electricity generation is realized, significantly
reducing your building’s carbon footprint.
3. 3 TdX Data Sheet
Achieve a 24-Month Payback Using Bluon TdX 20
Bluon TdX 20 delivers a return on investment in approximately 24 months of
operations. This payback was calculated based on average amp and run time
savings, average installation costs and average electricity kW rates.
About Bluon Energy
BluonEnergyisanenergy-focusedrefrigerantdeveloperandmanufacturerwithfreshideasfor
productsthatdeliversuperiorenergyperformanceinanenvironmentallyfriendlyway.Ourcurrent
innovationsgobeyondbeingjustanotherR-22replacementrefrigerant.We’vecreatedTdXtobe
theR-22answer.
ThechallengefacingtheHVAC-Rindustryistoprovideane ectivecoolingsolutionthatispositive
fortheenvironment,energye cientandcoste ective.TheBluonEnergyinnovationteambegan
researchingsolutionsforsystemsoveradecadeago.ThisresearchledtoBluon’snext-generation
R-22refrigerantreplacement,BluonTdX20.BluonEnergyrefrigerantsdeliverequaltoorgreater
coolingcapacity,consumelessenergyandresultinanROIofapproximately50%withapayback
in24monthsofoperations.ContactBluonEnergyat1-855-425-8686orinfo@bluonenergy.com.
Visitusatwww.bluonenergy.com.
ROI and payback gures are calculated based on average energy savings and installation costs.