Call Girls Jabalpur Just Call 9907093804 Top Class Call Girl Service Available
PET - Medical Cyclotrons: Overview and Recent Developments
1. Faisal Alrumayan
Cyclotron Section
Cyclotron & Radiopharmacuticles
21-24 May 2017
Medical Cyclotrons:
Overview and Recent Developments
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
2. Cyclotrons at KFSHRC
Cyclotron facilities
Cyclotron basics
Cyclotron Operations and Maintenance
Applications of Cyclotron beams
Cyclotron-produced manufactures
Recent developments
Summary
Outline
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
3. Cyclotron Facilities at KFSHRC
OLD Facility (1980)
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
4. Cyclotron Facilities at KFSHRC
OLD Facility (1980)
-The CS-30
Cyclotron
-1982
-4 particles
CNC Machine
Neutron Gantry
Physics/Research
Vault
The Hot Cells
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
Cyclotron control
Room
5. Cyclotron Facilities at KFSHRC
-The RDS-111 cyclotron
-started 2006
-11 MeV (Protons)
-The C-30 cyclotron
- Started in 2011
-Variable energy (Protons)
The Hot Cells
Chemistry Processing
Synthesizers
I-123 Target System
New Facility (2010)
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
PET Target Vault
6. Model Manufacturer Particles Energy Location Applications
CS30 The Cyclotron
Cooperation
P, d,He-3
And He-4
26.5, 15, 38, 15 KFSHRC Isotopes
RDS-111 Siemens P 11 KFSHRC Isotopes
RDS-111 Siemens P 11 KFSHRC-Jed Isotopes
RDS-111 Siemens P 11 Saad Hospital Isotopes
C-30 IBA P 30 KFSHRC Isotopes
TR-24 ACS P 24 NG-RUH Isotopes
C-18/9 IBA P, d 18/ 9 KFMH-Dammam Isotopes
TR-24 ACS P 24 KKUH-RUH Isotopes
BG-75 ABT P 7.5 KFMC-RUH Isotopes
(SD)
Varian Varian P 250 KFMC-RUH Treatment
Cyclotrons in Saudi Arabia
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
7. In the Cyclotron (particle
accelerator), high energy
sub-atomic particles are
bombarded on a non-
radioactive target
material to produce
radioactive isotopes
The Radiochemistry
section then processes the
target material to extract
radioisotopes in high purity
Following strict cGMP
guidelines, these radio-
isotopes are processed
further in our state-of-the-art
Radiopharmacy to produce
Radio-pharmaceuticals of
the highest purity, efficacy
and safety
Quality Control carries out
extensive testing to ensure that
the Radiopharmaceuticals
produced meet all requisite
specifications prior to release
Quality Assurance
implements and maintains an
effective Quality Management
System to assure that each batch of
Radiopharmaceutical released for
human use is of the highest quality
Nuclear Medicine
finished
Radiopharmaceuticals are
then packaged and shipped
to Nuclear Medicine centers
all over the Kingdom and
beyond
Production process of
PET Radiopharmaceuticals
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
9. Cyclotron Basics
First cyclotron:
1931, Berkeley
1kV gap-voltage
80keV Protons
E. Lawrence
1901-1959
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
First Cyclotron was built to proof the concept
10. Cyclotrons accelerates charged particles to higher energy.
Two fields are necessary to reach higher energies:
Magnetic field –
- To steer back charged particles or to make them rotate
- Does not accelerates them !!!
Electric field –
- Accelerates charged particles
- steer particles (focus or defocus)
Cyclotron Basics
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
11. ω – Angular velocity or Cyclotron Frequency measured in radians/s
Angular velocity of ions is a function of magnetic field, ion charge state and mass
We can apply between the Dees an RF accelerating voltage:
V = V0 cos wrf t
Cyclotron Basics
𝐹 𝑜 = 𝑞𝐵/2𝜋𝑚
𝑤 = 𝑞𝐵/m
𝑞𝑣𝐵 = 𝑚𝑣2/r
𝑣 = 𝑞𝐵/𝑚
Centrifugal forceLorentz force
r= mv/qB
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
12. Largest Cyclotron in
the world
Triumf- Canada
500 MeV!
Tf (500 MeV)=ti( few MeV)!
Nuclear Physics
Application
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
The cyclotron’s operation is based on the fact that the time per
revolution is independent of the speed of the particles and of the
radius of their path
13. Cyclotrons Ion Source
Multicusp 2mA at 28 kV
C-30
PIG Type Ion source
5 A at 3Kv
CS-30
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
14. Positive Particle Extraction
>> The beam is deflected by an electric field out of the cyclotron.
>> The advantages: the vacuum requirements are not as
stringent
>> The disadvantage: extraction is that it is not as efficient as the
negative ion extraction.
>> Activation inside the cyclotron is high.
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
15. Main Internal Cyclotron
component
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
Dees: for accelerations;
Magnet: for steering;
Extractor: getting the beam
out;
Supporting magnet elements;
Signals’ pickup elements;
16. Main external Cyclotron
component
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
Quadrupoles;
Steering magnet;
Beam stop;
Beam viewers;
Signals’ pickup elements;
Collimator.
17. Beam Transport System
Steering Magnet
1st Quadruple
2nd Quadruple
CCD Camera
PET Vault
Cyclotron
Vault
Beam Viewer
20 mm
40 mm
60 mm
Neutron Shatter
Drum Collimator
Switching Magnet
The C-30 Cyclotron
>> Beam line cyclotron is designed to transport Beams of various energy safely
>> What happens if beam is lost!
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
18. Cyclotron Targetry
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
Liquid Solid Gas
Target design is multidisciplinary field;
engineering, physics and chemistry;
Solid, Liquid and Gas.
Will be covered by Engs. Ahmed and Salam next lecture
19. Operating the cyclotron
(Driving a truck!)
Arrive 30 min before beam on target;
Warming up Cyclotron magnet (beam will be stable);
Vacuum level (>1e-7 mbar);
Careful tuning (all elements);
Observe changes during operation;
(Better to write it down your observations!).
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
C-30 Control software
20. Cyclotron Critical
Parameters: keep your eye on
Beam current : 10-6 A (MicroAmp)
Beam Energy: 106 MeV (Million Electron Volt)
Cyclotron vacuum: 10-8 mbar
Production Yield : mCi/uAhr.
Beam position : Directions
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
y = 9E-05x5 + 0.0069x4 -0.014x3 - 1.5393x2 +0.614x+ 98.297
0
20
40
60
80
100
120
-15 -10 -5 0 5 10 15
Distance (mm)
FWHM=10 mm
Dose= Beam current x Time
21. Maintenance of Cyclotron
Attempt to maximize performance of production equipment efficiently and
regularly.
Prevent breakdown or failures.
Minimize production loss from failures Increase reliability of the operating
systems.
Purpose
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
22. Responsibility
Routine maintenance usually performed by:
Well trained and qualified Engineer
External assistance may be carried out if equipment
under warranty.
Its good if internal technician is following maintenance
Example of PM Program: IBA
Maintenance of Cyclotron
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
23. Safety First.
Suitable tools. A list of suggested tools is provided in service manual
Test tools. Simple test tools that may be constructed are also described
Spare parts. Manufacture should advise what component for particular
part to be available.
Use shielding As mush As you Can
During maintenance Program
Maintenance of Cyclotron
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
24. Breakdown of Cyclotron
Lack/ Absence of schedule preventive maintenance
Heavy use on the cyclotron
Lack of qualification.
Sudden drop in electricity (frequently seen!)
Bad quality of used component (valves, etc).
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
25. Root Cause Analysis technique
RCA is a method used to solve problems (Whys principle)
Quick and efficient technique in identifying the problem
What could goes wrong!
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
26. What Could be highly dangerous is
The Habit when dealing with radiation equipment
Boring of following procedures and rules
From Our Experience
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
27. Applications of cyclotron Beams
Medical Applications
Diagnoses :Look into the body to see what is happening
Therapy: direct treatment (proton and carbon therapy)
Courtesy of www.isotopes.org
Courtesy of www.iba.com
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
28. Thin Layer Difference Method
Radiation
Detector
Activated Part
in the Machine
RTM - Radionuclide Technique in Mechanical Engineering
Applications of Cyclotron Beams
www.Zyklotron.com
Industrial Applications: Thine Layer Activation
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
31. The construction of the world’s smallest Radio Frequency Quadrupole (RFQ) for proton
acceleration was completed in September 2016.
The small size and low current is however what makes this design ideal for a wide range
of medical and industrial applications.
Doubling the operating frequency, more accelerating cells and a shorter length (2.5
MeV/m.
Hundreds of microAamp.
Up to the energy of 5 MeV.
A revolutionary mini- accelerator
(Credit: CERN)
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia
32. Conclusions
Cyclotrons are very useful machines for diagnoses and treatment;
Breakdown of cyclotrons could be catastrophic with respect to
patients who are waiting for their scan.
Why go for high energy cyclotron if the needs is less.
PET RADIOPHARMACUTICLES-PRODUCTION, QUALITY AND CLINICAL ASPECTS: 21-24 MAY 2017 , Riyadh, Saudi Arabia